Selamat Datang di Indotra.de
Masuk | Daftar
Anggota Prioritas Prioritas Indotra Tahun ke-15
ANDALAN INSTRUMENT GROUPANDALAN INSTRUMENT GROUP
http://indotra.de/aps_weatherstation/
\"JENCO INSTRUMENT - JEKEN Ultrasonic Cleaner - E_INSTRUMENT - ASSEMBLAD Gas Analyzer - KOEHLER - MITECH Ultrasonic thickness - DAVIS Weather Station - EUTECH - SOCOREX Liquid Handling - MEMMERT - BLUE GIZMO - HACH - OHAUS Balance - VITLAB - DURAN - KETT
Informasi Kontak
Nama:

Tn. Edy Girsang/ maria [Pemasaran]

E-mail:
Situs Web:

Pesan Instan:

Windows Live: http://indonetwork.co.id/46NDMyOTQ4OjE-kxmx-zMTQwMDI4NTI.html?op=sms 
Y!: edy_girsangta 
Nomor Telpon:

Nomor telpon Tn. Edy Girsang/ maria di BEKASI UTARA

Nomor Ponsel:

Nomor ponsel Tn. Edy Girsang/ maria di BEKASI UTARA

Nomor Faks:

Nomor faks Tn. Edy Girsang/ maria di BEKASI UTARA

Alamat:

Jl. Muchtar Tabrani , Bintang Metropol Blok A7 No16
BEKASI UTARA 17122, Jawa Barat
Indonesia

Alamat Tervalidasi

www.andalaninstrument.com
Rata-rata Tinjauan Pemakai
Tidak ada ulasan untuk perusahaan ini Menulis tinjauan

Unduhan (10)
Brosur Met One Auto....brosur Met One Data....Brosur Gray wolf multy....Brosur Chiyoda Pipet....3gtrack GPRS Data....3gtrack GPRS Modem3gtrack GPS Tracker GS....AIRMAR Ultar Sonic....Lihat semuanya

Jual

KOEHLER K45603 Automatic Distillation Analyzer 5000 Series
Hargainquiry
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Jumlah1 unit
Kemas & Pengirimanunit
Negara AsalAmerika Serikat
Test Method
The sample is evaporated and condensed under controlled conditions, and observations are made of the temperatures at which various percentages are recovered and/ or the percentages recovered at specified temperatures.

Features and Benefits
• Conforms to ASTM D86, D285, D4737 and related international specifications

• Pt-100 RTD probe with automatic temperature calibration system ( ° C or ° F)

• Windows® -based software package for PC control with LIMS export capabilities

• Automatic determination of initial boiling point ( IBP) , final boiling point ( FBP) , dry point and barometric and residue corrections

• Diagnostic system continuously ensures proper unit performance and user safety

• Automatic temperature and volume calibration

• Programmable distillation rate ( 2-15mL/ min)

• Ready for distillation groups 0 - 4

• Networking for up to 32 units

• Powerful CFC-free cooling & heating system

• Receiver chamber heating system to 60° C

• Precision level follower system with optical meniscus detector

• Integrated automatic fire extinguishing system with manual operation option

Click on the image to view a larger photo of the instrument. K45603 with Optional External PC picture shown.
K45603 Automatic Distillation Analyzer 5000 Series
The Koehler Automatic Distillation Analyzer is designed to perform optimal distillation analyses of gasolines, fuels, oils, solvents, aromatics, napthas, kerosenes, hydrocarbons, and other volatile products to ensure conformity to rigid quality control standards. The analyzers automatically perform tests, process results, and produce standard reports according to ASTM, ISO, DIN and related international test specifications.

Each Koehler Automatic Distillation Unit comes ready with the equipment, accessories, and features as standard to properly run distillation groups 0 to 4 per ASTM D86 and related test specifications. No additional accessories are required. The Windows® -based software package allows simple operator selection of the programmed settings for each distillation protocol. No complicated routines are needed to setup the unit. User-defined programs are easily created for customization of the analyzer.

Dry Point can be detected visually or by automatic detection for ASTM D850 and D1078 test methods. The unit is delivered ready with the PC board components already included as standard to perform the dry point analysis. It only requires the additional accessories of the dry point thermocouple, 200mL flask, and PTFE plug in order to perform the dry point detection analysis automatically.

Specifications
Conforms to the specifications of:
ASTM D86, D285, D850, D1078, D4737; D189 Section 10; DIN 51751; ISO
3405; IP123; JIS J2254; NF M 07-002
Electrical requirements:
120V 50/ 60Hz 20A
230V 50/ 60Hz 10A
Temperature
Distillation Range: 0 to 450° C ( ± 0.1° C accuracy)
Condenser: -5 to 60° C ( ± 0.1° C accuracy) ; closed loop system
Receiver Chamber: 0 to 60° C ( ± 0.1° C accuracy)
Distillation Parameters:
Distillation Rate: 2 to 15 mL/ min in 0.1mL increments, user selectable
Receiver Volume: 0 to 100 mL ( ± 0.01mL accuracy) by photoelectric
infrared detection of meniscus by level following system utilizing a precision stepper motor and a special calibrated glass receiver; automatic calibration of evaporated loss volume and automatic volume calibration system ensures highest accuracy
Barometric Pressure: Automatic barometric correction utility with
automatic sensor, range 550 to 900 mm Hg ( ± 1mm Hg accuracy)
Dry Point Detection: Dry point detection board is included with standard
equipment and only requires a dry point sensor, 200 mL flask and PTFE plug for ASTM D850 and D1078 tests.
Environment: Operates at 0 to 45° C ( 113° F)

Two Models are Available
The Automatic Distillation Analyzer 5000 series may be ordered for operation with an external PC ( purchased separately) or may be ordered with a built-in PC, internal touch screen monitor, virtual keyboard and mouse. An easy-to-use Windows® -based PC communication software expands user capabilities for data analysis and unit control. Distillation methods and parameters can be easily created or modified. Software calculates repeatability and reproducibility as per ASTM D86 as well as standard and deviation against reference materials. Test results are displayed in real-time and can include distillation curve and temperature with or without barometric compensation and/ or evaporation correction, distillation rate, heating power curve, master curve comparison, and zoom function for high resolution of heating and temperature curves. The heater compartment is rapidly cooled at the completion of a distillation run to reduce operator downtime. The analyzers are of rugged construction for instrument longevity with a modular design for easy routine maintenance.

Receiver Chamber Heating System
The receiver chamber heating system is ideal for samples that form waxes or other solids during distillation.
Anda mendapat [3] permintaan baru. Ke Menu Anggota