Description:

FS6000 Addressable fire control panel

The FS6000 control panel has a modular organization. One Line Driver Module is capable to drive 4 output lines. Each output line may be configured as an open Line or two output lines may be united in a closed Loop configuration. The maximum configuration is of 16 Lines or 8 Loops.

Each Line or Loop may contain a maximum of 127 address point ( detectors or adapters) . The system registers the condition of the addressable points – normal, fire condition or fault condition – and the conditions are displayed at the panel with specific combinations of LEDs. For each addressable point a text message displayed on the panel to determine the point’ s exact location may be assigned ( example Floor 5 Room12) . The communication between the panel and the addressable points is provided by two wire line and uses a specialized protocol. Protection against false alarm is available by repeated check ups of the activated detectors. The electromagnetic interference is filtered by the means of control equipment and software. In Loop configurations power is supplied from both sides and in case of a short circuit the short circuited segment is cut off by the isolators. All conditions and common faults are indicated and registered by the panel. It is possible to include conventional fire detectors in the FS6000 system using the addressable adapter.

The addressable adapter allows for conventional detectors to be included in the FS6000 Fire Alarm System.

Control, programming and signalization are carried out by the system’ s front panel, supplied with LED indicators, liquid crystal display and a keypad. The language select option is user-friendly.

Technical data

FIRE ALARM LINES

Maximum number of linear modules

4

Number of fire alarm lines ( loops) in a module

4( 2)

Maximum number of addresses in a line ( loop)

127

Maximum resistance of the two-wire fire alarm line

40&

Output resistance

20&

FIRE ALARM AND INTERLOCKING OUTPUTS

Open collector type 30V/ 0.3A

8

Relay, potential-free, switching 250V/ 8A

10

Controllable, relay, potential ( 25-35) V ( require end-of-line module)

2

FUNCTIONAL DESCRIPTION

Light indication for Test mode

Green

Light indication for Night mode

Red

Common purpose liquid crystal display

4 lines x 20 symbols

Built-in sound alarm for fire condition

Two-tonal

Built-in sound alarm for fault condition

One-tonal, discontinuous

Built-in real time clock

Yes

Selection of test and setup modes

Yes

Energy independent archive of events, registered by the system, containing event’ s type, date and time

200 events

Communication interface for external devices

RS 232

POWER SUPPLY

Mains

220V / 50Hz

Backup battery

24V / 7Ah

Consumption on battery

< 400mA

Dimensions

360 x 490 x 110 mm

Weight ( batteries not included)

10 kg