Anggota Gratis 
Bahasa :
CV. ANDALAN PRIMA SEJAHTERA
CV. ANDALAN PRIMA SEJAHTERA
http://indotra.de/cv_aps/
CV. ANDALAN PRIMA SEJAHTERA
Informasi Kontak
Nama:
Ibu REGINA / VANNY / VITHA [Direktur/CEO/Manajer Umum]
E-mail:
Situs Web:
Pesan Instan:
Y!: andalan1974@yahoo.com 
Nomor Telpon:
Nomor telpon Ibu REGINA / VANNY / VITHA di JAKARTA
Nomor Ponsel:
Nomor ponsel Ibu REGINA / VANNY / VITHA di JAKARTA
Nomor Faks:
Nomor faks Ibu REGINA / VANNY / VITHA di JAKARTA
Alamat:
Jl. muchtar tabrani, Perum Bintang Metropol Blok A7/16 Bekasi
JAKARTA, Jakarta
Indonesia
Rata-rata Tinjauan Pemakai

Tidak ada ulasan untuk perusahaan ini

Menulis tinjauan

Katalog Produk

TSP-2 Total Suspended Particulate Air Sampling System
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Kemas & Pengiriman1 unit
Negara AsalAmerika Serikat

Keterangan

Total Suspended Particulate High Volume Air Sampling System is designed for fast, accurate collection of suspended particulates in accordance to U.S. EPA specifications.

These complete air sampling systems, available with various modular accessories, are designed to meet the EPA requirements for sampling airborne particulates at a known flow rate for a determined amount of time, allowing for proper calculation of airborne particulate concentrations.

Basic System

The basic TSP Air Sampling System includes High Volume Air Sampler with vertical mount flowmeter; SH810 8"x10" Filter Holder Assembly and SAM Aluminum Outdoor Shelter.

8"x10" Glass Fiber Filters recommended for Total Suspended Particulate Air Sampling

Accessory Items

Timers

DTM-1 and DTM-2 Digital 7-Day Timer Turns Air Sampler "ON" and "OFF" at set times, 24 hours a day, 7 days a week. All functions are digital and quartz crystal controlled; includes digital clock with 1/4-in. LED display and 7.2 VDC rechargeable stand-by battery; intuitive programming format

MT-1 and MT-2 Mechanical 7 Day Timer Turns Air Sampler "ON" and "OFF" at set times ±15 minutes, 24 hours a day, 7 days a week. Specify Model MLT-1 for 120 VAC, 60 Hz; Model MLT-2 for 230 VAC, 50 Hz

DTM-4CDT Digital Countdown Timer Turns Air Sampler "OFF" after preset times. Features LCD display and thumb-wheel setting dials. (range from 99,999 hours to 1 second). Size: 3" x 4-1/4" x 5" (7.6 cm x 10.8 cm x 12.7 cm); Weight: 1.75 lbs. (0.8 kg). Usable for 110-125 VAC, 220-240 VAC and 24 VDC.

ETI-1 and ETI-2 Elapsed Time Indicator Shows sampler run time in hours and hundreths (99,999.99 hours). Standard models are non-resettable mechanical models. Specify Model ETI-1 for 120 VAC, 60 Hz.; Model ETI-2 for 220 VAC, 50 Hz. (Re-settable model ETI-1R is also available for 120 VAC.)

Constant Flow Controllers Models FC-1 and FC-2 - Automatically maintains a constant mass flow through an High Volume Air Sampler regardless of filter loading, atmospheric conditions and line voltage. Specify Model FC-1 for 115 VAC; Model FC-2 for 230 VAC. [requires SH810 filter holder assembly]

Models FC-1ETM and FC-2ETM include built-in non-resettable Elapsed Time Indicator.

Models FC-1MLT and FC-2MLT include built-in Mechanical 7-Day Timer and non-resettable Elapsed Time Indicator.

Flow Recorder - Models FR-1 and FR-2 - Provides a permanent record of High Volume Air Sampler performance during a 24-hour period. Specify Model FR-1 for 115 VAC; Model FR-2 for 230 VAC.

Calibration Kit - Models CKHV810 - U.S. EPA prescribed method for accurate calibration of High Volume Air Samplers. U.S. EPA recommends that High Volume Air Samplers be re-calibrated at least once per year (or when major components such as the motor or flowmeter are changed). Model CKHV810 can be used with 4" or 8" x 10" filter holder assemblies.

PM10 Size Selective Inlets - for U.S. EPA PM10 environmental air sampling. Staplex® PM10 Size Selective Inlet is available separately as Part No. PM10-SSI for conversion of existing TSP (Total Suspend Particulate) High Volume Air Sampling Systems to PM10 System