HIOKI 3153 AUTOMATIC INSULATION / WITHSTANDING HiTESTER
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Kemas & Pengiriman1 unit
Negara AsalJepang

Keterangan

Programable testing, full remote control, Automatic Insulation Withstanding Tester

This electrical safety test instrument series is designed for insulation resistance and voltage withstand testing of electrical devices and components according to various safety standards. A multitude of automation and labor-saving features are provided to ensure effective testing for a wide variety of requirements and test conditions. Select the most appropriate model for your applications.
- Insulation and AC/DC continuous voltage withstand testing
- Safety standards compliance testing
- Stores up to 10 sets of test conditions (10 each for insulation and voltage withstand)
- Zero-V Switching (voltage withstand testing)
- Electrical Discharge function (DC voltage withstand, insulation testing)
- Automated testing support
- Interlock Protect function
- Remote controllable

Basic specifications : Withstanding test section

Testing voltage : 0.2 kV to 5.00 kV AC, 500VA (maximum 30 minutes)
0.2 kV to 5.00 kV DC, 50VA (continuance)
Voltage setting method : Digital setting
Waveform : Same as the power supply waveform
Frequency : Same as the power supply frequency
Measurement range : Current: 0.01 to 100.0 mA, ±(2 % f.s. +5 dgt.) 10 mA/100 mA AC (Average value rectified, effective value display)

Basic specifications : Insulation test section

Testing voltage : 50 V to 1000 V DC
Measurement range : 0.1 m-ohm to 9999 m-ohm, 4 ranges

Basic specifications : general

Judgment function : Contents: UPPER-FAIL / PASS / LOWER-FAIL (Digital setting window comparator method)
Timer section : Setting range: 0.3 to 999 seconds
Interfaces : EXT I/O, EXT SW, RS-232C, GP-IB
Display : Fluorescent tube display (digital), Analog meter
Monitor function : Output voltage, detection current
Power supply : 100 V to 120 V AC / 200 to240 V AC, (50/60 Hz), 1000 VA max.
Dimensions, mass : 320 mm(12.60 in)W × 155 mm(6.10 in)H × 480 mm(18.90 in)D, 18 kg (634.9 oz)
Accessories : H.V. TEST LEAD 9615 (high voltage side and return, 1 each), Power cord (1), spare fuse (1)