Anggota Gratis 
Bahasa :
CV. ANDALAN PRIMA SEJAHTERA
CV. ANDALAN PRIMA SEJAHTERA
http://indotra.de/cv_aps/
CV. ANDALAN PRIMA SEJAHTERA
Informasi Kontak
Nama:
Ibu REGINA / VANNY / VITHA [Direktur/CEO/Manajer Umum]
E-mail:
Situs Web:
Pesan Instan:
Y!: andalan1974@yahoo.com 
Nomor Telpon:
Nomor telpon Ibu REGINA / VANNY / VITHA di JAKARTA
Nomor Ponsel:
Nomor ponsel Ibu REGINA / VANNY / VITHA di JAKARTA
Nomor Faks:
Nomor faks Ibu REGINA / VANNY / VITHA di JAKARTA
Alamat:
Jl. muchtar tabrani, Perum Bintang Metropol Blok A7/16 Bekasi
JAKARTA, Jakarta
Indonesia
Rata-rata Tinjauan Pemakai

Tidak ada ulasan untuk perusahaan ini

Menulis tinjauan

Katalog Produk

HIOKI 3930 HIGH VOLTAGE SCANNER[11 Mar. 2009, 22:23:16]
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Kemas & Pengiriman1 unit
Negara AsalJepang

Keterangan

Automatic Multipoint Testing of High Voltages

- Maximum of 32 Channels
In single mode, an individual 3930 can measure eight channels, and up to four units can be connected together for a total of 32 channels.In multi-mode, the 3930 has four high and low channels, respectively;and when four units are connected, up to 16 high and low channels can be tested.
- Safe Design
The 3930 can handle up to 5kV of direct current or alternating current.
- The 3930 is a general-purpose high voltage scanner that can not only be controlled
by using the HIOKI 3153's program function, but also by general-purpose logic and sequencers.
- Primary Applications
Insulation withstand voltage testing for electrical and electronic equipment
Insulation withstand voltage testing for electric components

Functions :

Operation modes : Multi- and single modes ( External switch )
Number of channels : Multi-mode; 4 high channels and 4 low channels
Single mode; 8 high channels and a common channel
Rated voltage used : AC 5 kV/DC 5 kV
Control method : General-purpose control

Relay area :

Maximum open and closed voltage : 5000 V DC, 5000 V AC
Maximum open and closed current : 1.0 A (open and closed capacity: 50 W)
Contact point indirect contact resistance : 500 mor less, with 1 mA AC
Contact point maximum capacity : 50 W
Operation time : 6 ms or less
Recovery time : 6 ms or less

General specifications

Degree of Accuracy Standards for current leakage when applying voltage
Single mode, no output cable, and all output relays
Turned on for both AC and DC.
When applying DC (1000 V); 0.1 µA or less/unit
When applying AC (5 kV, 50/60 Hz only); 0.4 mA
or less/unit
(Differs depending on the status of the connection cable)
Operation temperature range 0°C to 40°C, 80% rh or less (no condensation)
Storage temperature range -10°C to 50°C, 90% rh or less (no condensation)
Operation environment Indoors, altitude of 2000 m or less
Withstand voltage High voltage terminal - between the chassis:
AC 10 kV, 10 mA, 1 min
Power VSCV 24 V DC, ±10%
(applied using the control signal input connector)
Maximum rated power 12 VA
Measurements Approx. 316 (W) × 100 (H) × 350 (D) mm
Mass Approx. 4.2 kg
Standard accessories Connection cables H.V. TEST LEAD 9615

General specifications

Degree of Accuracy Standards for current leakage when applying voltage
Single mode, no output cable, and all output relays
Turned on for both AC and DC.
When applying DC (1000 V); 0.1 µA or less/unit
When applying AC (5 kV, 50/60 Hz only); 0.4 mA
or less/unit
(Differs depending on the status of the connection cable)
Operation temperature range 0°C to 40°C, 80% rh or less (no condensation)
Storage temperature range -10°C to 50°C, 90% rh or less (no condensation)
Operation environment Indoors, altitude of 2000 m or less
Withstand voltage High voltage terminal - between the chassis:
AC 10 kV, 10 mA, 1 min
Power VSCV 24 V DC, ±10%
(applied using the control signal input connector)
Maximum rated power 12 VA
Measurements Approx. 316 (W) × 100 (H) × 350 (D) mm
Mass Approx. 4.2 kg
Standard accessories Connection cables H.V. TEST LEAD 9615

General specifications :

Degree of Accuracy : Standards for current leakage when applying voltage
Single mode, no output cable, and all output relays
Turned on for both AC and DC.
When applying DC (1000 V); 0.1 µA or less/unit
When applying AC (5 kV, 50/60 Hz only); 0.4 mA
or less/unit
(Differs depending on the status of the connection cable)
Operation temperature range : 0°C to 40°C, 80% rh or less (no condensation)
Storage temperature range : -10°C to 50°C, 90% rh or less (no condensation)
Operation environment : Indoors, altitude of 2000 m or less
Withstand voltage : High voltage terminal - between the chassis:
AC 10 kV, 10 mA, 1 min
Power : VSCV 24 V DC, ±10%
(applied using the control signal input connector)
Maximum rated power : 12 VA
Measurements : Approx. 316 (W) × 100 (H) × 350 (D) mm
Mass : Approx. 4.2 kg