Anggota Gratis 
Bahasa :
CV. ANDALAN PRIMA SEJAHTERA
CV. ANDALAN PRIMA SEJAHTERA
http://indotra.de/cv_aps/
CV. ANDALAN PRIMA SEJAHTERA
Informasi Kontak
Nama:
Ibu REGINA / VANNY / VITHA [Direktur/CEO/Manajer Umum]
E-mail:
Situs Web:
Pesan Instan:
Y!: andalan1974@yahoo.com 
Nomor Telpon:
Nomor telpon Ibu REGINA / VANNY / VITHA di JAKARTA
Nomor Ponsel:
Nomor ponsel Ibu REGINA / VANNY / VITHA di JAKARTA
Nomor Faks:
Nomor faks Ibu REGINA / VANNY / VITHA di JAKARTA
Alamat:
Jl. muchtar tabrani, Perum Bintang Metropol Blok A7/16 Bekasi
JAKARTA, Jakarta
Indonesia
Rata-rata Tinjauan Pemakai

Tidak ada ulasan untuk perusahaan ini

Menulis tinjauan

Katalog Produk

HIOKI 3196 POWER QUALITY ANALYZER[9 Mar. 2009, 21:15:44]
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Kemas & Pengiriman1 unit
Negara AsalJepang

Keterangan

Monitor and record the quality of power to analyze the cause of trouble when it occurs !
The 3196 is your most reliable and complete instrument for power quality troubleshooting :

* Measure power factor
* Sags
* Swells
* Flicker
* Transients
* Harmonics to the 50th
* High Frequency transient
* Detection and waveform display
* Four current and Four voltage channels

Let the HIOKI 3196 see what you have been missing.

Basic specifications :

Measurement lines Single-phase/two-wires, Single-phase/three-wires, Three-phase/three-wires, Three-phase/four-wires
Measurement items : Impulsive voltage quality:Transient overvoltage (Impulse), RMS voltage quality:Voltage swell, Voltage dips, Voltage interruption, Power quality:Frequency, Voltage, Current, Current peak, Active/Reactive/Apparent power, Power factor (displaced power factor), Three phase quality:Voltage unbalance ratio, Current unbalance ratio, Harmonic quality (Up to 50th order):Harmonic voltage, Harmonic current, Harmonic power, Inter-harmonic voltage, Inter-harmonic current, Harmonic voltage current phase angle, Total harmonic voltage distortion, Total inter-harmonic current distortion (THD-F, THD-R), Total inter-harmonic voltage distortion ratio, Total inter-harmonic current distortion ratio (THD-F, THD-R), K factor, Flicker:Measures delta- V10 flicker (Japanese domestic), or IEC flicker [Pst, Plt] (international standards),
Measurement ranges : Voltage ch1 to ch3: 150.00 to 600.00 V AC rms-3 ranges, ch4: 60.000 to 600.00 V AC rms-4 ranges, or 60.000/600.00 V DC-2 ranges, Current (When using 100 A sensor): 50.000/100.00 A AC rms-2 ranges, Current (When using 500 A sensor): 50.000/500.00 A AC rms-2 ranges, Current (When using FLEXIBLE CLAMP ON SENSOR 9667): 500.00 A / 5000.0 A AC rms-2 ranges, Current (When using CLAMP ON SENSOR 9669): 1000.0A AC rms-1 range, Current (When using CLAMP ON SENSOR 9694): 5.0000A / 50.000 A AC rms-2 ranges, Power: Combination pattern of voltage and current ranges
Measurement method : Transient overvoltage: 2 mega-sampling/sec, Harmonic wave: 2048 point (10 cycle at 50 Hz, or 12 cycle at 60 Hz), Other effective value: 256 point/one cycle
Memory capacity : 13 MB
Interface : PC card slot (9727/ 9728 PC card, 256MB to 512MB), RS-232C, LAN (10BASE-T)
Power supply : 12 V DC output AC ADAPTER 9458 (Universal 100 to 240 V AC, 50/60 Hz), or BATTERY PACK 9459 (7.2 V/2450 m Ah Ni-MH)
Dimensions, mass : 298 mm(11.73 in)W × 215 mm(8.46 in)H × 67 mm(2.64 in)D, 2.25 kg (79.4 oz)...within battery
Accessories : Voltage cord (one set), AC ADAPTER 9458 (1), BATTERY PACK 9459 (1), shoulder strap (1), LAN connector cover (1), marking label (1), Down96 (data download software)